AHU Standards Explained: EN 1886, EN 13053, EN 308 and AHRI, and Where AHULab Fits

Air Handling Units

AHU Standards Explained: EN 1886, EN 13053, EN 308 and AHRI, and Where AHULab Fits

What each Eurovent and AHRI standard requires from an air handling unit, and how our updated AHULab software takes a unit from design to certification, drawings and cost.

Applied Engineering Team
Oct 16, 2026
5 min read

Introduction to AHULab Standards

An air handling unit is a chain of sections: filters, coils, fans, heat recovery, humidifiers and dampers, all inside one casing. Its performance depends on every section and on the casing itself. That is why AHU manufacturers selling into Europe, the Middle East and North America are increasingly asked to prove their performance against Eurovent and AHRI standards.


Why standards matter
Certification programmes test sample units and then check that the manufacturer's selection software predicts their performance. Every unit sold must be calculated the same way as the units that passed the test. The software behind the catalogue is therefore as important as the hardware.


Eurovent: EN standards
  • EN 1886: Mechanical performance of the casing: casing strength, casing air leakage, filter bypass leakage, thermal transmittance, thermal bridging and acoustic insulation.
  • EN 13053: Rating and performance of units, components and sections, including air velocity, heat recovery and fan power classes.
  • EN 308: Test procedures for the performance of air-to-air heat recovery devices.


AHRI standards
  • AHRI 1350 / 1351: Mechanical performance of air handling unit casings (I-P / SI).
  • AHRI 430 / 431: Performance rating of central station air handling units and their supply fans(I-P / SI).
  • AHRI 410: Forced-circulation air-cooling and air-heating coils.
  • AHRI 1060 / 1061: Air-to-air exchangers for energy recovery ventilation equipment(I-P / SI)


Where AHULab fits
AHULab calculates units according to the Eurovent standards EN 1886, EN 13053 and EN 308, and the AHRI standards 1350/1351, 430/431, 410 and 1060/1061. It supports manufacturers in obtaining Eurovent and AHRI certification, and keeps every unit they sell on the same calculation basis as the units that were tested.


Sections included
  • Air washer
  • Pre-filter
  • Bag filter
  • HEPA filter
  • Electrostatic filter
  • Bypass with coil
  • Coil (DX, chilled water, heating, steam)
  • Economizer / mixing box
  • Electric heater
  • Eliminator
  • Access section
  • Empty section
  • Fan section
  • Fresh air louver
  • Fresh air intake
  • Full inlet damper
  • Heat recovery (thermal wheel, cross-plate and counter-cross-plate HEX 
  • Sand trap louver
  • Sound attenuator
  • Steam humidifier
  • Return plenum
  • Supply plenum
  • Exhaust plenum


Coils and refrigerants
  • Design and simulation of chilled water, hot water, steam and DX coils.
  • DX coils with 210+ refrigerants from the Applied refrigerant list.
  • Chilled water coils with water, ethylene glycol, propylene glycol, sodium chloride, calcium chloride, methanoland more.
  • Steam at saturation or superheat, as the designer requires.
  • Condensers workable up to 55 °C ambient. Low-temperature applications down to −80 °C are also supported.
  • Psychrometric analysis of the air, in SI, I-P or mixed units.


Fans and components
  • Fans: design and simulation with Nicotra, Nicotra Gebhardt, Comefri, Kruger, Yilida, Ziehl-Abegg, Deton, Rosenberg and ebm-papst. Other brands can be added on request.
  • Heat recovery: thermal wheels and plate heat exchangers.
  • Heat pipes: horseshoe and heat recovery types.
  • Economizer, electric heater and steam humidifier design and simulation.
The built-in component library includes, for example:
  • Fans: Nicotra, ebm-papst, Deton, Rosenberg, Comefri, Kruger, Ziehl-Abegg, Yilida
  • Motors: Leroy-Somer, Siemens, Teco, Watt
  • Energy wheels: Heatex, Klingenberg, Hoval, DRI, Semco, Recuperator
  • Plate heat exchangers: Heatex, Klingenberg, Hoval, Recuperator
  • Heat pipes: SPC, or our Applied heat pipe software
Other brands can be added by agreement.


Construction options
  • Insulation: injected foam, fiberglass, rock wool or polyurethane, at different densities.
  • Panel thickness: 25, 30, 42, 50 or 60 mm.
  • Casing: galvanized or stainless steel, from 0.5 to 1.5 mm.
  • Profiles: aluminium, mild steel, galvanized steel, PVC or thermal break.
  • Layout: horizontal or vertical units, single or double deck, with sections merged horizontally and vertically.


Costing and integration
  • Bill of materials with complete details and prices.
  • Unit costing: enter the cost of raw materials such as aluminium, copper and stainless steel, and of components such as motors, fans and filters. AHULab returns the unit price at your chosen margin.
  • Currencies: edit prices with different currency rates.
  • Unit weight calculation.
  • Projects: save, open, edit and save as.
  • Integration with ERP and CRM systems.


Optional modules
These can be added to your AHULab version if required:
  • Air-cooled condensing unit
  • Water-cooled condensing unit
  • Hot gas reheat
  • Desiccant dehumidifier thermal wheel
  • Duct furnace section
  • Heat pipe heat recovery
  • Heat pipe horseshoe
  • Custom technical submittal report
  • Quotation report in your own format
  • Design feature in addition to simulation in the coil section
  • AutoCAD drawing of the coil with circuiting details
  • Coil heat exchanger manufacturing drawings
  • Panel design with AutoCAD, DXF and PDF drawings
  • AutoCAD drawing of the whole unit
  • Manufacturing drawings of outer and internal parts, including coil details
  • BIM drawing
  • Multiple languages


Who it's for
Design engineers Technical engineers R&D engineers Consultant engineers Lab test engineers Production engineers Cost estimation engineers.


Key takeaways
  • EN 1886 covers the casing, EN 13053 the unit and its sections, and EN 308 heat recovery testing.
  • AHRI 1350/1351, 430/431, 410 and 1060/1061 cover casings, units and fans, coils and energy recovery.
  • Certification depends on calculating every unit sold the same way as the units that were tested.
  • AHULab covers the whole chain: sections, coils, fans, construction, drawings, costing and integration.

More Articles